How To Order
Operating Conditions
1. Operating Media: Dry and lubricated air, or non-corrosive gas. The maximun particle diameter must be less than 40μm. 2. Air Supply Pressure: The minimum supply pressure is 2 Bar (30 psi). The maximum supply pressure is 8 Bar (120 psi). 3. Operating Temperature: Standard (NBR O-ring): -20°C ~ 80°C (-4°F ~ 175°F); Low Temperature (L NBR O-ring): -35°C ~ 80°C (-30°F ~ 175 °F); High Temperature (Viton O-ring): -15°C ~ 150°C (5°F ~ 300°F). 4. Travel adjustment: Have adjustment range of ± 5° for the rotation at 0° and 90° 5. Lubrication: Under normal operating condition, need not accrete lubricant. 6. Application: Either indoor or outdoor. 7. Highest pressure: The maximum input pressure is 10 Bar (145 Psi). |